T-10-02SSA: Analog Time Switch

T-10-02SSA: ANALOG TIME SWITCH
Control a circuit requiring 24 hour, 7 day scheduling with the  rain tight SS Series Analog Time Switch by Nightscaping®.
Materials: 22-gauge stainless steel case 3 wire, 3 foot weatherproof cord 20AMP duplex receptacle
Dimensions: 6 3/4″ x 3 3/4″ x 4 ½”

Mounting Instructions:
Mount the T-10-02SSA Analog Time Switch a minimum of 36″ above ground in a location that allows clearance to open and remove switch cover. The case features a bracket with two keyhole slots 2 ½” on center for easy installation.

Time Switch Rating:
12.5AMP 120VAC resistive, 1350 Watt Tungsten, 1 HP @ 120VAC. Power consumption equals approximately 1VA. T-10-02SSA/PC – Built-in photocell.

 


 

ETC-300SS ~ Digital Time Switch

ETC-300SS: Digital Time Switch
Control a circuit requiring 24 hour, 7 day scheduling with the rain tight SS Series Digital Time Switch by Nightscaping®. Program individual days of the week or block programs based on the demands of any individual lighting system.
Materials: 22-gauge stainless steel case 3 wire, 3 foot weatherproof cord 20AMP duplex receptacle
Dimensions: 6 3/4″ x 3 3/4″ x 4 ½”

Mounting Instructions:
Mount the ETC-300SS Digital Time Switch a minimum of 36″ above ground in a location that allows clearance to open and remove switch cover. The case features a bracket with two keyhole slots 2 ½” on center for easy installation.

 

Time Switch Rating:
12.5AMP 120VAC resistive, 1350 Watt Tungsten, 1 HP @ 120VAC. Power consumption equals approximately 1VA.
Running Reserve:
In case of power failure, the running reserve feature will maintain the time of day and program for approximately 100 hours.


 

Non-Raintite Transformers: V12-100VA, 150VA, 250VA

Non-Raintite Transformers: V12-100VA, 150VA, 250VA
These transformers reduce regular 120V household current to 12V alternating current (AC). They are not weatherproof and
therefore, carry a two year warranty.

Electrical Characteristics:
Reduce 120V to 12V 60 cycles A.C. Grounded and shielded between primary and secondary side, 2500V Dielectric. Multi-tap primary winding.Tamper proof fustat on
12V side. Fustat (supplied): 10A for 100VA, 15A for 150VA, 25A for 250VA.

Transformer Sizing:
Add A.C. watts consumed for all lamps on the circuit. The transformer must be sized equal to or greater than the sum of all lamp wattages. The VA rating indicated on the transformer label indicates the total wattage allowed on the specific unit. Notice: These transformers must be installed in accordance with local electrical codes. Installation by a licensed electrical contractor is recommended.

Model                       VA Rating 12V       Amperage 12V        Draw 120V        Height                   Width                   Depth                   Weight
V-12-100-VA            100W(VA)                 8.33                        833AMPS           3.875″(9.8cm)       3.25″(8.3cm)        5.5″(14cm)            5.2 lbs
V-12-150-VA            150W(VA)                12.50                       1.25AMPS          3.875″(9.8cm)       3.25″(8.3cm)        5″(14cm)               5.5 lbs
V-12-250-VA            250W(VA)                20.83                       2.09AMPS         4.625″(11.7cm)      4.00″(10.2cm)     .0″(15.2cm)           8.7 lbs

Fustats
Nightscaping® incorporates double element S-type fustats in our Powercenter™ systems for two reasons:

  1. Reliability – Fustats operate on the integrity of the secondary circuit. If a field wiring problem occurs, the fustat will trip and prevent potential damage from occurring to the system. Fustats are tamper proof.
  2. Troubleshooting – Fustats indicate the reason for failure. They provide insight into whether the problem is a result of either a direct short or system overload.

 