| SS
Series Features |
| Five
Sizes: |
100VA,
150VA, 250VA,
500VA, 1000VA
UL, CSA, wet location
listed |
| Voltage
Switch: |
Four
position on/off voltage regulating switch |
| Terminal
Blocks: |
Color
coded, oversized 60-amp terminal blocks for easy
cable connections |
| Toggle
Switch: |
Manual
on/off control module override |
| Wiring
Cavity: |
Large
wiring cavity for ease of installation |
| Conduit
Adapter: |
½"
conduit adapter for hard-wire installations |
| |
| Materials
|
| Case: |
22-gauge
stainless steel uni-body construction |
| Power
Cord: |
3-foot-3
conductor insulated power cord and molded plug
connector for easy plug-in to household current
(GFCI protected outlet), mounting hardware and
hanging template. |
| Electrical
Characteristics |
|
|
Reduces 120V
to 12V 60 cycles A.C. (240V to 12V 50 cycles A.C.
available by quote). |
|
|
Grounded and
shielded (ground shield between primary and secondary).
2490V Dielectric. |
|
|
amper-proof
fustat(s) on 12V side. |
|
|
Multi-tap primary
winding. |
|
| Powercenter
Sizing |
|
|
Add up A.C.
watts consumed by all lamps on circuit (refer
to lamp chart). The Powercenter circuit
capacity must be equal to or greater than total
lamp wattage. Refer to Powercenter label
for total wattage capacity of the unit. |
| Powercenter
Placement |
|
|
Mount Powercenters
a minimum of 12" above ground. |
|
|
Ideally, Powercenters
should be placed in the center of the installation. |
| Powercenter
Placement with Photocell |
|
|
The photocell must always
see the sky. Do not hide in plant materials. Lights
from fixtures must not shine on photocell. When
timer and photocell modules are combined the photocell
can be used to turn the system on and the timer
set to turn the system off. |
| Options |
|
|
Refer to control
module sheet. |
|
|
Powercenters may
be ordered in your choice of optional powder-coat
finishes for a slight up charge. Contact factory
for a quote. |