| Printable Transformer Cut Sheet (PDF) |
SS Series Features |
|
Five Sizes: |
100VA, 150VA, 250VA, 500VA, 1000VA |
Voltage Switch: |
Four position on/off voltage regulating switch |
Terminal Blocks: |
Color coded, oversized 60-amp terminal blocks for easy cable connections |
Toggle Switch: |
Manual on/off control module override |
Wiring Cavity: |
Large wiring cavity for ease of installation |
Conduit Adapter: |
½" conduit adapter for hard-wire installations |
|
|
|
Materials |
|
Case: |
22-gauge stainless steel uni-body construction |
Power Cord: |
3-foot-3 conductor insulated power cord and molded plug connector for easy plug-in to household current (GFCI protected outlet), mounting hardware and hanging template. |
Electrical Characteristics |
|
• |
Reduces 120V to 12V 60 cycles A.C. (240V to 12V 50 cycles A.C. available by quote). |
• |
Grounded and shielded (ground shield between primary and secondary). 2490V Dielectric. |
• |
amper-proof fustat(s) on 12V side. |
• |
Multi-tap primary winding. |
|
|
Powercenter™ Sizing |
|
• |
Add up A.C. watts consumed by all lamps on circuit (refer to lamp chart). The Powercenter™ circuit capacity must be equal to or greater than total lamp wattage. Refer to Powercenter™ label for total wattage capacity of the unit. |
Powercenter™ Placement |
|
• |
Mount Powercenters™ a minimum of 12" above ground. |
• |
Ideally, Powercenters™ should be placed in the center of the installation. |
Powercenter™ Placement with Photocell |
|
• |
The photocell must always see the sky. Do not hide in plant materials. Lights from fixtures must not shine on photocell. When timer and photocell modules are combined the photocell can be used to turn the system on and the timer set to turn the system off. |
Options |
|
• |
Refer to control module sheet. |
• |
Powercenters™ may be ordered in your choice of optional powder-coat finishes for a slight up charge. Contact factory for a quote. |